OPBOX Ultrasonic Testing Unit Key Benefits

Self-contained design connectable to any PC computer
Indexing (encoder) controls capability
Internal battery or AC power supply
Extensive software with the Lab Windows platform

The OPBOX device, in a form of box of the size of the notebook computer, contains ultrasonic testing card, pulser&receiver and computer interface. It has a separate power supply with own battery and may be connected to any computer through a standard Centronics interface. The unique design of OPBOX unit and its full interchangeability with each and every PC computer systems makes it perfect for any specialized field and lab ultrasonic applications as well as for educational, research and training purposes.

This innovative device is suitable for the variety of manual and automatic ultrasonic testing applications (flaw detection, precision thickness measurements, TOFD etc.). It can be even operated with any automatic scanning hardware systems or multiplexed channels units (the OPBOX through its indexing control is fully capable of integrating such devices). It can work in pulse-echo mode (with one transducer sending and receiving) and with two transducers (transmit mode, TOFD etc.). Included software is Windows 9x, NT compatible. The device can also work as standard digital oscilloscope. The OPBOX unit can be equipped with the range of the customized transducers.

Technical data

A/D converter:  
-Resolution: 8 bits
-Sampling frequency: 50 or 100MHz 1
Analog parameters:  
-Input channels: 2 (switched): send & receive and receive
-Input amplifier gain: 0dB, 6dB, 14dB, 20dB, 26dB, 34dB, 40dB (hardware amplifier on the card)1 additional 33dB in echo mode (amplifier in the pulser&receiver box) total possible gain: 110dB (with software amplification)
-Minimal sensitivity: 0.1mV/Div -1mVpp (with software amplification)
-Maximal sensitivity: 50mV/Div - 0.5Vpp
-Averaging: 1 – 256
-Bandwidth: 0,1 – 25MHz
-Input impedance: 50W, 10pF
Data buffer: 256, 512, 1K or 32K 1
Trigger: Internal (software), external, max 2 kHz
Delay time: Post trigger 256us, measurement accuracy better than 1ns
Pulser: 8 steps voltage adjustable broadband pulser, from 50V to 300V, the voltage depends on the used transducer, 20ns fall time, a separate match box size unit
Interface: Parallel Port (Centronics DB25 – female)
Power supply: AC 220/110V, approx. 4 hours of work with the internal Sealed Lead-Acid battery
Size: 255x295x50mm
Weight: 2700g

1 - software selected feature

Software features

Two windows: RF signal in the main window, in the second window the option of zoom, FFT (Fast Fourier Transformation), rectified signal and filtered signal;
Software amplification, filtering and averaging (allows the elimination of the noise interference when working with very noisy and/or weak signals);
Build in DAC and TCG curves;
Three signal memories, each signal can be stored and compared with any other signal.
Support for Lab Windows Platform
Customized software versions are also available

 